New energy fuses are actually fuses, which can protect electrical equipment from overcurrent damage. Therefore, each fuse has a rated specification, and the fuse will blow when the current exceeds the rated specification. The early fuse was created by Edison, used to maintain the incandescent lamp that was relatively expensive at that time!
I still remember the hours, the house often cuts out at dusk, it is the peak time for lighting, cooking, watching TV, and talking about hygiene. Every household is using electricity, so the circuit is overloaded, the new energy fuse is overheated, and then it is black. . Fuses have sacrificed to maintain countless light bulbs and televisions. Of course, it seems that using fuses for overload maintenance is too unsafe!
There are two types of fuse materials: one is round wires with different diameters made of low melting point materials such as lead-tin alloys, namely fuses. Because of their low melting point, it is not easy to extinguish the arc, and has little effect on each part of the fuse. Used in small current circuits. The other is high melting point materials such as silver, copper, etc., which are used in circuits with high currents.
Each type of new energy fuse has two parameters: rated current and fusing current. When the current through the fuse is less than the rated current, the fuse will not blow; as long as it exceeds its rated current and reaches the fusing current, the fuse will blow. The greater the current passing through the new energy fuse, the faster the new energy fuse will blow.
As a general rule, a new energy fuse should fuse within 1 hour when the current passing through 1.3 times its rated current; when passing 1.6 times the rated current, it should fuse within 1 hour; when passing 2 times the rated current, The fuse should be blown instantaneously. The fusing current is generally twice the rated current of the fuse. It can be seen that the fuse is very inflexible in terms of overload maintenance and should not be used for overload maintenance. It is mainly used for short-circuit maintenance.
When choosing a new energy fuse, it must be based on the operating current practiced in the circuit, and must not be used in accordance with the specifications of the fuse. Regarding the fuse of the sub-master fuse of the household electric energy meter, the selection method is: the rated current of the new energy fuse is greater than or equal to the sum of the rated current of all electrical appliances, and less than or equal to the rated high current of the energy meter.